5.4 Mounting the M-Control PCB
Mount the M-Control PCB 1 to the right of the set value initiator 2.
Connect the compressed air hose 4 to the compressed a ir
maintenance unit 8.
Fix the two compressed air hoses 7 from the machine head onto
the throttle valves / solenoid valves 5 and 6.
Plug the electric cables 3 into the corresponding sockets.
Note
If the function of the keys L”and“R are permuted, swap the
compressed air hoses 7 at the solenoid valves.