Instruction manual
5.4 Mounting the M-Control PCB
–
Mount the M-Control PCB 1 to the right of the set value initiator 2.
–
Connect the compressed air hose 4 to the compressed a ir
maintenance unit 8.
–
Fix the two compressed air hoses 7 from the machine head onto
the throttle valves / solenoid valves 5 and 6.
–
Plug the electric cables 3 into the corresponding sockets.
Note
If the function of the keys “L”and“R” are permuted, swap the
compressed air hoses 7 at the solenoid valves.
21
GB
21
765 4 3
8