Instruction manual
5.1.1 Lighting transformer connection to network voltage
Attention! Danger of electric injury!
The lighting transformer is not switched-off by the main switch
(EN 60 204-31)! At the lighting installation and repair works in the
transformer box, e .g. a fuse replacement, the network plug must be
disconnected from the network unconditionally.
A. The machine is equipped with Efka DC1550/DA321G
–
Pull the network plug form the socket.
–
Screw out 4 screws on the front plate of the control box.
–
Remove the front plate.
–
Pull the cable of the lighting transformer through the canal (1) in
the control box.
–
Take out the black rubber bushing (2).
–
Pierce the bushing with a screwdriver.
–
Pull the lighting transformer cable through the arisen hole.
–
Put the rubber bushing back again.
–
Gradually push the terminal openers (3) and (4) with a small
screwdriver until the terminals (5) and (6) open.
–
Connect the blue conduit (6) to the terminal and brown conduit (5)
to the terminal.
–
Screw the front plate back again.
–
Fix the lighting transformer cable against plucking out
(e.g. w ith a stick tape to the network supply cord).
13
GB
26 5 1
65 4 3