Instruction manual

5.1.1 Lighting transformer connection to network voltage
Attention! Danger of electric injury!
The lighting transformer is not switched-off by the main switch
(EN 60 204-31)! At the lighting installation and repair works in the
transformer box, e .g. a fuse replacement, the network plug must be
disconnected from the network unconditionally.
A. The machine is equipped with Efka DC1550/DA321G
Pull the network plug form the socket.
Screw out 4 screws on the front plate of the control box.
Remove the front plate.
Pull the cable of the lighting transformer through the canal (1) in
the control box.
Take out the black rubber bushing (2).
Pierce the bushing with a screwdriver.
Pull the lighting transformer cable through the arisen hole.
Put the rubber bushing back again.
Gradually push the terminal openers (3) and (4) with a small
screwdriver until the terminals (5) and (6) open.
Connect the blue conduit (6) to the terminal and brown conduit (5)
to the terminal.
Screw the front plate back again.
Fix the lighting transformer cable against plucking out
(e.g. w ith a stick tape to the network supply cord).
13
GB
26 5 1
65 4 3