7 (18)
4.4 Setup Screen
The Setup Screen offers the possibility to:
1. Set the “Reference Position”
2. Active the “User Patterns” option
3. Select the 0-backtack type
4. Exit the screen with the “Back” button
During setup the machine is blocked.
4.4.1 Reference position
The reference position is used to determine all relevant positions related to needle bar rotation and
transport.
After power up, two stitches are needed for the control to determine the exact position. In case the machine
hasn’t been in operation for at least two stitches after power up, the text “not set” is displayed. The
reference position will set automatically within 2 stitches.
Only in rare cases ( e.g.: new plc soft- or hardware) the reference position has to be set.
If you are not sure about the correct setting of the reference position, follow the steps indicated in & 4.5.1.1
Checking the reference position
4.4.1.1 Checking the reference position
Turn the hand wheel in forward direction until the current
sector is indicated by a value 1 upto 20,
Continue turning the hand wheel until the arrow on the left-
hand side of the wheel levels with the 60º indication on the
wheel.
In this position, the reference position should show the
value “1”
If a different value is displayed follow the steps indicated in
& 4.5.1.2 Setting the reference position
Setup screen
1
Setup screen
1
2
3
4