Operation Manual
Set-up instructions
94 Operating instructions 867 - 02.0 - 08/2015
7.12.3 Establishing equipotential bonding
The earthing cable conducts away any static charging of the
machine head.
Figure 66: Establishing equipotential bonding
1. Tilt the machine head.
2. Feed the earthing cable from the connection (1) on the rear
side of the controller through the cutout in the table plate and
plug it onto the tab connector (2) on the base plate.
Danger to life due to electric shock.
Disconnect the power plug before establishing
equipotential bonding.
Make sure the power plug cannot be unintention-
ally reinserted.
DANGER
2
1
(1) - Connection at the controller (2) - Tab connector