Maintenance
72 Operating instructions 867 - 02.0 - 08/2015
Water condensation accumulates in the water separator of the
maintenance unit.
Figure 47: Water level in the maintenance unit
Check the water level:
1. Check the water level every day.
Important: The condensation water must not rise up to the
level of the filter element (1).
Drain water as required:
1. Switch off the sewing machine at the main switch.
2. Place the collection tray under the drain screw (3).
3. Remove the compressed air hose from the compressed air
supply.
4. Unscrew the drain screw (3) completely.
5. Allow water to drain into the collection tray.
6. Re-tighten the drain screw (3).
7. Connect the compressed air hose to the compressed air sup-
ply.
8. Switch on the sewing machine at the main switch.
0
2
8
4
6
10
1
2
3
(1) - Filter element
(2) - Water separator
(3) - Drain screw
Machine damage possible if there is too much water.
Too much water can cause damage to the machine.
Check the water level every day and drain the condensation
water if there is too much water in the water separator.
ATTENTION