Operation Manual

Set-up instructions
100 Operating instructions 867 - 02.0 - 08/2015
7.12.8 Fitting the M-Control circuit board
Figure 70: Fitting the circuit board
1. Fitting the circuit board:
Machines with a binder:
between the frame (1) and cable duct (2)
Machines with switchable needle bars:
At the right next to the setpoint device angle bracket (3)
Danger to life due to electric shock.
Disconnect the power plug before fitting the circuit
board.
Make sure the power plug cannot be unintention-
ally reinserted.
DANGER
1
2
3
(1) - Frame (2) - Cable duct
(3) - Setpoint device angle bracket