Number Location Description Possible cause Remedial action
1052 Sewing motor Excess current Sewing motor cable
Sewing motor
Controller
Check the sewing motor cable
Check the sewing motor
Check the controller
1053
Sewing motor Excess voltage Mains voltage too high Check the mains voltage
1055 Sewing motor Overload Sewing motor (blocked/not
moving freely)
Controller
Check the sewing motor
Check the controller
1056 Sewing motor Excess
temperature
Sewing motor
(not moving freely)
Controller
Check the sewing motor
Check the controller
1058 Sewing motor Speed Sewing motor Check the sewing motor
1059 Sewing motor Standstill
monitoring
Sewing motor
Reference switches
Check the sewing motor
Check the reference switch
1120 Sewing motor Initialization Sewing motor
Sewing motor cable
Reference switches
Check the sewing motor
Check the sewing motor cable
Check the reference switch
1205 Sewing motor Not in ET Sewing motor
Sewing motor cable
Reference switches
Switch off the machine.
Check the sewing motor
Check the sewing motor cable
Check the reference switch
1301 Sewing motor Referencing
Timeout
Reference switches
Sewing motor
Controller
Check the reference switch
Check the sewing motor
Check the controller
1302 Sewing motor Current supply
error
Sewing motor
Sewing motor cable
Controller
Check the sewing motor
Check the sewing motor cable
Check the controller
1310 Sewing motor Communication
problem
Sewing motor
Sewing motor cable
Reference switches
Check the sewing motor
Check the sewing motor cable
Check the reference switch
1320 Sewing motor General
Sewing motor
error
Sewing motor
Sewing motor cable
Reference switches
Check the sewing motor
Check the sewing motor cable
Check the reference switch
2101 Stepper motor
x-axis
Referencing:
Timeout
Reference switches
Stepper motor
Controller
Check the reference switch
Check the stepper motor
Check the controller
2152 Stepper motor
x-axis
Excess current Stepper motor
Controller
Check the stepper motor
Check the controller
2153 Stepper motor
x-axis
Excess voltage Stepper motor
Controller
Check the stepper motor
Check the controller
2155 Stepper motor
x-axis
Overload Stepper motor
Controller
Check the stepper motor
Check the controller
2156 Stepper motor
x-axis
Excess
temperature
Stepper motor
Controller
Check the stepper motor
Check the controller