Number Location Description Possible cause Remedial action
1052 Sewing motor Excess current • Sewing motor cable
• Sewing motor
• Controller
• Check the sewing motor cable
• Check the sewing motor
• Check the controller
1053
Sewing motor Excess voltage • Mains voltage too high • Check the mains voltage
1055 Sewing motor Overload • Sewing motor (blocked/not
moving freely)
• Controller
• Check the sewing motor
• Check the controller
1056 Sewing motor Excess
temperature
• Sewing motor
(not moving freely)
• Controller
• Check the sewing motor
• Check the controller
1058 Sewing motor Speed • Sewing motor • Check the sewing motor
1059 Sewing motor Standstill
monitoring
• Sewing motor
• Reference switches
• Check the sewing motor
• Check the reference switch
1120 Sewing motor Initialization • Sewing motor
• Sewing motor cable
• Reference switches
• Check the sewing motor
• Check the sewing motor cable
• Check the reference switch
1205 Sewing motor Not in ET • Sewing motor
• Sewing motor cable
• Reference switches
• Switch off the machine.
• Check the sewing motor
• Check the sewing motor cable
• Check the reference switch
1301 Sewing motor Referencing
Timeout
• Reference switches
• Sewing motor
• Controller
• Check the reference switch
• Check the sewing motor
• Check the controller
1302 Sewing motor Current supply
error
• Sewing motor
• Sewing motor cable
• Controller
• Check the sewing motor
• Check the sewing motor cable
• Check the controller
1310 Sewing motor Communication
problem
• Sewing motor
• Sewing motor cable
• Reference switches
• Check the sewing motor
• Check the sewing motor cable
• Check the reference switch
1320 Sewing motor General
Sewing motor
error
• Sewing motor
• Sewing motor cable
• Reference switches
• Check the sewing motor
• Check the sewing motor cable
• Check the reference switch
2101 Stepper motor
x-axis
Referencing:
Timeout
• Reference switches
• Stepper motor
• Controller
• Check the reference switch
• Check the stepper motor
• Check the controller
2152 Stepper motor
x-axis
Excess current • Stepper motor
• Controller
• Check the stepper motor
• Check the controller
2153 Stepper motor
x-axis
Excess voltage • Stepper motor
• Controller
• Check the stepper motor
• Check the controller
2155 Stepper motor
x-axis
Overload • Stepper motor
• Controller
• Check the stepper motor
• Check the controller
2156 Stepper motor
x-axis
Excess
temperature
• Stepper motor
• Controller
• Check the stepper motor
• Check the controller