Operation Manual
Settings via the software
Operating Instructions 841 - 00.0 - 09/2014
37
6 Settings via the software
6.1 Indexer program parameters
Symbol Parameters Values Meaning
Indexer program
(Index prg.)
1 … 99 • Selection of indexer program to be sewn
Sequence On/Off • Asks whether the same buttonhole should be always be
sewn or a selection of several buttonholes.
• On: several buttonholes are sewn
• Off: a single buttonhole is sewn
Buttonhole program
number
(Buttonhole no.)
1 … 52 • Selection of the relevant buttonhole program number
(change of parameters for the buttonhole to be sewn during
buttonhole programming)
Blouse On/Off • On: Womens' blouse
With a womens' blouse the lay mark is on the left of the
infeed device.
• off: Mens' shirt
With a mens' shirt the lay mark is on the right.
Number
(No.)
1 ... 20 • Number of buttonholes to be sewn in this indexer program
Edge distance
(Edge dist.)
0.0 ... 620.0 • This parameter defines the distance in millimeters from the
first buttonhole to the lay point.
If the value 0.0 is input here, the first buttonhole will be
sewn without the feed unit transporting the sewing material
(for shirts only). If another value is input here, the sewing
material will transported by this value before the first button-
hole is sewn.
Uniform
(unif.)
On/Off This parameter sets the type of distances between the
buttonholes.
• On: Uniform arrangement
Since the distance between the buttonholes is always the
same with a uniform arrangement of buttonholes, only one
value needs to be entered with the following parameter.
• off: Non-uniform arrangement
In case of a non-uniform arrangement, all distances
between the buttonholes need to be entered.
Distance
(Dist.)
0.0 ... 620.0 Depending on the “uniform” parameter setting, the distance
between the buttonholes may be set here.
• Uniform arrangement
This parameter sets the distance in millimeters between the
buttonholes.
• Non-uniform arrangement
This parameter (dist.1) sets the distance between the first
and second buttonhole.
This parameter (dist.2) sets the distance between the sec-
ond and third buttonhole.
The number of parameters depends on the number of but-
tonholes to be sewn in this indexer program.