Operation Manual

Operation
34
Operating Instructions 841 - 00.0 - 09/2014
Figure 14: Draining the water condensation
Maintenance steps
1. Place the collection tray under the drain screw (3).
2. Unscrew the drain screw (3) completely.
3. Allow water to drain into the collection tray.
4. Tighten the drain screw (3).
Cleaning the filter element
ATTENTION
Machine damage due to too much water
Too much water can result in damage to the machine.
Check the water level every day and drain water, if necessary.
(1) - Filter element
(2) - Water separator
(3) - Drain screw
WARNING
Risk of injury
Switch off the machine at the main power switch
and disconnect it from the pneumatic network
before you clean the filter element.
ATTENTION
Damage to the paintwork due to solvent-based cleaners.
Solvent-based cleaners damage the filter.
Use only solvent-free substances for washing out the filter tray.