Operation Manual

Operation
Operating Instructions 841 - 00.0 - 09/2014
33
Figure 13: Setting operating pressure
Setting steps
1. Pull the adjustment knob (1) up.
2. Turn the turning handle until the pressure indicator (2) indicates 6 bar:
clockwise: to increase pressure
counterclockwise: to reduce pressure
3. Push the adjustment knob (1) down.
Draining the water condensation
Water condensation may accumulate in the water separator of the pres-
sure controller.
Correct setting
Water condensation cannot rise up to the filter element (1).
Check the water level in the water separator on a daily basis.
ATTENTION
Machine damage due to incorrect pressure
Incorrect pressure can result in damage to the machine. Make sure that
the machine is only used when the operating pressure is set correctly.
0
2
8
4
6
10
2
1
(1) - Adjustment knob (2) - Pressure indicator
WARNING
Risk of injury
Switch off the machine at the main power switch
and disconnect it from the pneumatic network
before you drain the water from the water separa-
tor.