Operation Manual

Operation
32
Operating Instructions 841 - 00.0 - 09/2014
DA 10 can be obtained under the following part number at DA sales offices:
9047 000011 – 250 ml
9047 000012 – 1 l
9047 000013 – 2 l
9047 000014 – 5 l
5.12.3 Lubrication of the upper part of the machine
The central oil lubrication system supplies all bearing positions with oil
from the reservoir.
Correct setting
The oil level is between the minimum level marking and the maximum lev-
el marking.
Figure 12: Lubrication of the upper part of the machine
1. Check the oil level indicator every day.
If the oil level is below the minimum level marking (3):
Pour oil through the refill opening (1) but no higher than the maximum
level marking (2).
5.12.4 Pneumatic system
Setting operating pressure
Correct setting
The operating pressure is 6 bar.
Check the pressure on the pressure indicator every day. The pressure
cannot deviate by more than 1 bar.
ATTENTION
Machine damage due to incorrect oil level
Too little or too much oil can result in damages to the machine.
Check the oil level every day and top up the oil, if necessary.
MAX
MIN
1
2
3
(1) - Refill opening (2) - Maximum level marking
(3) - Minimum level marking