Operation Manual
Operating Instructions 650-10 - 02.0 - 10/201586
EDIT mode Other sewing step parameters
A tap on the Other sewing step parameters button will bring up
an overview of all available parameters.
Fig. 57: Other sewing step parameters
6.5.2 Creating a new sewing program
(PROGRAMMING)
Prerequisite:
• Operating mode EDIT is displayed.
Parameters Meaning
Foot Stroke Alternation Sewing foot alternation whilst the needle is
in the sewing material
Value range: 0 – 2.5 mm
Foot Pressure Sewing foot pressure
Value range: 1 – 10
Maximum Speed Max. sewing speed/speed
Value range: 100 – 4000