Operation Manual

Operating Instructions 650-10 - 02.0 - 10/201578
Information
If changed in AUTO operating mode, the new correction value
remains active until the controller changes to the next program.
AUTO mode Other program parameters
A tap on the Other program parameters button will bring up an
overview of all available parameters.
Fig. 51: Other program parameters
6.4.2 Sewing process
1. Select a sewing program ( p. 74).
The program number and name of the sewing program are
displayed on the user interface. If no name has been saved
for the selected sewing program, <No
Name> is displayed.
Parameters Meaning
Foot Pressure Sewing foot pressure
Value range: 110