Operation Manual

Operating Instructions 650-10 - 02.0 - 10/2015 49
Current step
•Use / to select the parameter
•Use /to switch to the next/previous step
Press the OK key to edit other parameters for the
step, Edit mode
( p. 51)
Fullness
Value range: Upper fullness: 016
Lower fullness: 0 – 6
Use the numeric keys 016 to select the desired
fullness.
Use the plus/minus key to select upper or lower
fullness.
Or:
Use the additional pedal to select the fullness, if fitted
Stitch length
Value range: 1.04.0 mm
•Use / to select the parameter
•Use / to change the stitch length
Thread tension
Value range: 199
•Use / to select the parameter
•Use / to change the thread tension
Curve support
Value range: 0 – 6
•Use / to select the parameter
•Use / to change the curve support
Length of the current step in mm
Symbol Meaning