Operation Manual

Operating Instructions 650-10 - 02.0 - 10/2015 141
2901 Error Referencing timeout Switch the machine off and
on again
Check the clamping of the
stepper motor
3010 Error Controller: 100 V voltage
error
Check the connections
Replace the control
3011 Error Controller: 100 V voltage
error
Check the connections
Replace the control
3012 Error Controller: 100 V voltage
error (I²T)
Switch the machine off and
on again
Check the connections
Replace the control
3020 Error Short circuit in 24 V input or
output
Check the connections
Replace the control
3021 Error Short circuit in 24 V input or
output
Check the connections
Replace the control
3022 Error Short circuit in 24 V input or
output (I²T)
Switch the machine off and
on again
Check the connections
Replace the control
3030 Error Sewing motor phase error Test sewing motor phases
(R
= 2.8, high impedance
to PE)
Replace the encoder
Replace the sewing motor
Replace the control
3104 Warning Foot pedal not in rest
position
Setpoint device defective
Do not step on the foot
pedal when starting up
the
machine
Replace the setpoint device
4440
4459
Error OP3000 control panel:
Internal error
Switch the machine off and
on again
Perform a software update
Replace the control panel