Operation Manual

Operating Instructions 650-10 - 02.0 - 10/2015136
2362 Error Z-axis stepper motor
disturbance
(IDMA auto
increment)
Switch the machine off and
on again
2371 Error Watchdog Switch the machine off and
on again
Perform a software update
Contact customer service
2372 Error Stepper motor overvoltage:
Stepper motor card
defective
Replace the control
2373 Error Z-axis stepper motor error Check the connection
Test stepper motor phases
(R
= 2.8, high impedance
to PE)
Replace the encoder
Replace the stepper motor
Replace the control
2374 Error Software error Perform reset
Perform a software update
Contact customer service
2375 Error Magnet wheel search Check the connection
Test stepper motor phases
(R
= 2.8, high impedance
to PE)
Replace the encoder
Replace the stepper motor
Replace the control
2377 Error Stepper motor overload (I²T) Remove the cause of the
stiff movement or blockage
Replace the stepper motor
Replace the control
2378 Error Encoder error Check the connection of
the encoder cable and
replace, if necessary
Replace the control
2379 Error Current sensor:
Stepper motor card
defective
Controller defective
Replace the control
Code Type Possible causes Remedial action