Operation Manual

Operating Instructions 650-10 - 02.0 - 10/2015 127
1006 Error Sewing motor error:
Max. speed exceeded
Sewing motor cable
defective
Sewing motor defective
Switch the machine off and
on again
Replace the encoder
Perform reset
Replace the sewing motor
Contact customer service
1007 Error Error in the reference run Replace the encoder
Eliminate stiff movement in
the machine
1008 Error Sewing motor encoder error Replace the encoder
1010 Error Sewing motor synchroniza-
tion error:
External synchronizer
plug
(Sub-D, 9-pin) not
connected
Connect plug of external
synchronizer to controller,
use correct connection
(Sync)
Replace the reference
switch or synchronizer
Only required for machines
with transmission!
1011 Error Sewing motor synchroniza-
tion error (Z pulse)
Switch off the controller,
use handwheel to turn and
switch on the controller
again
If error is not corrected,
check encoder
1012 Error Sewing motor synchroniza-
tion error
Replace the synchronizer
1051 Error Sewing motor timeout:
Cable to sewing motor
Reference switch defective
Reference switch defective
Replace the cable
Replace the reference
switch
1052 Error Sewing motor overcurrent:
Sewing motor cable
defective
Sewing motor defective
Controller defective
Replace the sewing motor
cable
Replace the sewing motor
Replace the control
1053 Error Sewing motor overvoltage Check the mains voltage
1054 Error Internal short circuit Replace the control
Code Type Possible causes Remedial action