Operating instructions

24.6 Menu items 500 (Configuration automatic buttonholer)
24.6.1 Menu item 501 (Loading position)
Via this menu item the desired loading position can be set.
Input: 0 68 (mm)
Standard: 68
The value entered corresponds to the distance from the cutting point.
The value “0” corresponds to the cutting-open position.
The standard value is identical with the seam beginning position.
Quit the menu item with key ESC”.
24.6.2 Menu item 502 (Throw width)
In this menu the throw width is adjusted between “wide” and “narrow”.
Attention: Danger of breakage !
The throw width must match the mechanical position of the throw
eccentric.
See chapter 2.3
Input: 1 = Narrow
2=Wide
Quit the menu item with the ESC”key.
24.6.3 Menu item 503 (Thread monitor)
In this menu the needle thread monitor is set.
The set value means:
0 = Thread monitor off
1 10 = Number of stitches after which the sewing process
is aborted because of thread breakage
Input: 0 14
Standard: 7
Quit the menu item with the ESC”key.
24.6.4 Menu item 504 (Duty cycle of the cutting block)
The duration of the incision can be set individually so that the material
to be processed is cut open accurately and no longer than required.
Input: 200 600
Standard: 200
Quit the menu item with the ESC”key.
3