Operating instructions

5. Aligning the needle bar parallel to the looper turret
Caution: Danger of injury!
Switchthemainswitchoff.
Adjust the needle bar only with the main switch switched off.
Standard checking
The needle bar 1 and the looper turret 3 must be in parallel position.
Remove the cutting block.
Unscrew the finger protection and the head cover.
Note !
Do not separate the cable from the head cover.
Switch the machine on.
The machine runs to its initial position.
Switch the machine off.
Stake out the looper turret with arresting pin 2.
Position an angle 5 at the right side 6 of the looper turret.
Check whether the screw 7 at the needle bar guide 8 abuts on the
angle.
Correction
Loosen the screws 9 at the toothed belt wheel 10.
Turn the needle bar guide 4 correspondingly.
Tighten the screws 9 at the toothed belt wheel 10.
Switch the machine on.
Check the needle bar position.
3
11
1
2
4
3