Operation Manual
Maintenance
Operating Instructions 610-10/630-10 - 00.0 - 01/2016 87
Checking the oil level
Proper setting
The oil level must always be between the minimum level mark (3)
and the m
aximum level mark (2).
Refilling oil
For topping off the oil reservoir, use on
ly lubricating oil DA 10 or
oil of equivalent quality with the following specifications:
• Viscosity at 40 °C: 10 mm²/s
• Flash point: 150 °C
You can order the lubricating oil from our sales offices using the
fol
lowing part numbers:
NOTICE
Property damage from inco
rrect oil level!
Too little or too much oil can damage the machine.
Top off oil as described.
NOTICE
Property damage from incorrect oil!
Incorrect oil types can result in damage to the machine.
Use only oil that corresponds to the following specifications.
Container Part no.
250 ml 9047 000011
1 l 9047 000012
2 l 9047 000013
5 l 9047 000014