Operation Manual
Settings via software
Operating Instructions 610-10/630-10 - 00.0 - 01/2016 69
Mode EDIT Other sewing step parameters
A tap on the Oth
er sewing step parameters button will bring up
an overview of all available parameters. Before you can make
changes, you need to select the corresponding step in the
program.
Abb. 39: Other sewing step parameters in operating mode EDIT
5.5.2 Creating a new sewing program
(PROGRAMMING)
Prerequisite:
• Operating mode EDIT is displ
ayed.
Parameter Meaning Value range
Thread Tension at Hook Looper thread tension 1 – 99
Maximum Speed Maximum speed 100 – 4000