Operation Manual
Operation
Operating Instructions 610-10/630-10 - 00.0 - 01/2016 33
Fig. 15: Setting the sewing foot pressure (2)
Important
Do not adjust the sewing foot pressure of the center foot unless
the feed dog pokes out of the throat plate or the handwheel (4) is
in position E.
To adjust the sewing foot pressure of
the center foot:
1. Loosen the nut (3).
2. Setting the sewing foot pressure:
• Increase sewing foot pressure = turn the nut (2) clockwise.
• Reduce sewing foot pressure = turn the nut (2) counter-
clockwise.
Important
Hold the adjusting wheel (1) in place during the adjustment in
order to
prevent the pressure of the top feed foot from being
altered inadvertently!
3. Re-tighten the nut (3).
(4) - Handwheel
④