Operating Instructions 610-10/630-10 - 00.0 - 01/2016130
3011 Error Controller: 100 V voltage error Check the connections
Replace the controller
3012 Error Controller: 100 V voltage error
(I²
T)
Switch the machine off and on
again
Check the connections
Replace the controller
3020 Error Short circuit in 24 V input or
output
Check the connections
Replace the controller
3021 Error Short circuit in 24 V input or
output
Check the connections
Replace the controller
3022 Error Short circuit in 24 V input or
output (I²T)
Switch the machine off and on
aga
in
Check the connections
Replace the controller
3030 Error Sewing motor phase error Test sewing motor phases
(R = 2.8, high impe
dance to
PE)
Replace the encoder
Replace the sewing motor
Replace the controller
3104 Warning Pedal not in rest position
Setpoint device defective
Do not press the pedal when
st
arting up the machine
Replace the setpoint device
4440
4459
Error OP3000 control panel:
Internal error
Switch the machine off and on
aga
in
Performing a software update
Replace the control panel
6000
6299
Error Internal error Switch the machine off and on
aga
in
Performing a software update
Contact Customer Service
6351
6354
Error Controller defective (I²C) Replace the controller
6360 Warning Data on machine ID not
admissable
Replace the controller
Code Type Possible causes Remedial action