Operation Manual

Troubleshooting
Operating Instructions 610-10/630-10 - 00.0 - 01/2016 123
2277 Error Stepper motor overload (I²T) Remove the cause of the stiff
movement or blockage
Replace the stepper motor
Replace the controller
2278 Error Encoder error Check the connection of the
encoder
cable and replace,
if necessary
Replace the controller
2279 Error Current sensor:
Stepper motor card defective
Controller defective
Replace the controller
2280 Error Direction of rotation Replace the encoder
Check plug assignment and
change, if necessar
y
Check wiring in machine distribu-
tor and change it, if necessary
Test stepper motor phases and
c
heck for correct value
2281 Error Error in the reference run Replace the reference switch
2282 Error Stepper motor current error Remove the blockage
Check the encoder cable and
r
eplace, if necessary
Replace the stepper motor
2283 Error Stepper motor overcurrent Replace the sewing motor cable
Replace the stepper motor
Replace the controller
2284 Error Software error Perform reset
Performing a software update
Contact Customer Service
2285 Error Stepper motor insulation error Check motor phase and PE for
low-
impedance connection
Replace the encoder
Replace the stepper motor
2286 Error Software error Perform reset
Performing a software update
Contact Customer Service
Code Type Possible causes Remedial action