Operation Manual

Troubleshooting
Operating Instructions 610-10/630-10 - 00.0 - 01/2016118
1060 Error PowerParts Replace the controller
1061 Error Sewing motor disturbance:
Encoder defective
Sewing motor defective
Switch the machine off and on
aga
in
Replace the encoder
Replace the sewing motor
Contact customer service
1062 Error Sewing motor disturbance (IDMA
auto increment)
Switch the machine off and on
aga
in
1120 Error Software error:
Parameter not initialized
Performing a software update
1203 Information Sewing motor:
Position not reached
Switch the machine off and on
aga
in
Performing a software update
Contact Customer Service
1302 Error Sewing motor current error:
Sewing motor blocked
Encoder cable not connected
or
defective
Encoder defective
Remove the blockage
Check the encoder cable and
r
eplace, if necessary
Replace the sewing motor
1330 Error Sewing motor not responding Switch the machine off and on
aga
in
Performing a software update
Contact Customer Service
2102 Error X-axis stepper motor:
Stepper motor not moving
fr
eely or blocked
Encoder cable not
connected or defective
Stepper motor cable not
connected or defective
Encoder defective
Stepper motor defective
Remove the cause of the stiff
movement o
r blockage
Check the encoder cable and
r
eplace, if necessary
Replace the encoder
If the stepper motor is not supplied
with cu
rrent:
Check the stepper motor cable
and
replace, if necessary
Replace the stepper motor
2103 Error X-axis stepper motor step losses:
Stiff mechanical movement or
blocka
ge
Remove the cause of the stiff
mechanical movement or
blockage
Code Type Possible causes Remedial action