Operation Manual

Troubleshooting
Operating Instructions 610-10/630-10 - 00.0 - 01/2016 117
1008 Error Sewing motor encoder error Replace the encoder
1010 Error Sewing motor synchronization
err
or:
External synchronizer plug
(
Sub-D, 9-pin) not connected
Connect plug of external
s
ynchronizer to controller,
use correct connection (Sync)
Replace the reference switch or
s
ynchronizer
Only required for machines with
tr
ansmission!
1011 Error Sewing motor synchronization
err
or (Z pulse)
Switch off the controller, use
handwheel to turn and switch on
the controller again
If error is not corrected, check
encoder
1012 Error Sewing motor synchronization
err
or
Replace the synchronizer
1051 Error Sewing motor timeout:
Cable to sewing motor
Reference switch defective
Reference switch defective
Replace the cable
Replace the reference switch
1052 Error Sewing motor overcurrent:
Sewing motor cable defective
Sewing motor defective
Controller defective
Replace the sewing motor cable
Replace the sewing motor
Replace the controller
1053 Error Sewing motor overvoltage
Check the mains voltage
1054 Error Internal short circuit Replace the controller
1055 Error Sewing motor overload (I²T):
Sewing motor not moving freely
or blocked
Sewing motor defective
Controller defective
Remove the cause of the stiff
movement o
r blockage
Replace the sewing motor
Replace the controller
1056 Error Sewing motor overtemperature:
Sewing motor not moving freely
Sewing motor defective
Controller defective
Correct the cause of not moving
fr
eely
Replace the sewing motor
Replace the controller
1058 Error Sewing motor speed greater
than setpoint:
Reference switch defective
Sewing motor defective
Replace the reference switch
Replace the sewing motor
Code Type Possible causes Remedial action