Operation Manual
Setup
Operating Instructions 610-01/630-01 - 02.0 - 08/201562
6.4.3 Pneumatic connection
The pneumatic system of the sewing station and the auxiliary
devices must be supplied with moisture-free compressed air.
The supply pressure must be between 8 and 10 bar.
Fig. 30: Pneumatic connection
Connecting the compressed air maintenance unit
1. Connect the connection hose (3) (Part no. 0797 003031) to the
co
mpressed air supply with an R ¼" hose coupling.
Setting the operating pressure
The operating pressure is 6 bar.
This can be read on the pressure gauge (2).
To increase the pressure:
• Raise the rotary handle (1) and turn it clockwise.
To reduce the pressure:
• Raise the rotary handle (1) and turn it anti-clockwise.
(1) – Rotary handle
(2) – Pressure gauge
(3) – Connection hose
①
②
③