Operation Manual

Operation
Operating Instructions 610-01/630-01 - 02.0 - 08/201552
Pneumatic
system
Check the
water
level in
the pressure
controller
Clean the filter
element
Check the leak
tightness of
the s
ystem
The water level must not rise to the
level of t
he filter element (1).
Drain the water under pressure from
the water
separator (2) after unscrew-
ing the drain screw (3).
Dirt and condensation are separated
by the filter element (1).
Disconnect the sewing machine
from the compressed air supply.
Unscrew the drain screw (3).
The pneumatic system of the sewing
mach
ine must be depressurized.
Unscrew water separator (2).
Unscrew filter element (1). Wash out
the dirty filter
tray and filter element
using petroleum ether (no solvent)
and blow clean.
Reassemble the maintenance
unit again.
40 operating
ho
urs
500 operating
ho
urs
500 operating
ho
urs
Maintenance Explanations Interval