Operation Manual
Operation
Operating Instructions 610-01/630-01 - 02.0 - 08/201552
Pneumatic
system
Check the
water
level in
the pressure
controller
Clean the filter
element
Check the leak
tightness of
the s
ystem
The water level must not rise to the
level of t
he filter element (1).
• Drain the water under pressure from
the water
separator (2) after unscrew-
ing the drain screw (3).
Dirt and condensation are separated
by the filter element (1).
• Disconnect the sewing machine
from the compressed air supply.
• Unscrew the drain screw (3).
The pneumatic system of the sewing
mach
ine must be depressurized.
• Unscrew water separator (2).
• Unscrew filter element (1). Wash out
the dirty filter
tray and filter element
using petroleum ether (no solvent)
and blow clean.
• Reassemble the maintenance
unit again.
40 operating
ho
urs
500 operating
ho
urs
500 operating
ho
urs
Maintenance Explanations Interval