Operation Manual
Maintenance
Instruction manual 550-532 - 00.0 - 07/201582
10.3Servicing the pneumatic system
10.3.1 Setting operating pressure
Fig. 37: Checking pneumatic system
Proper setting
The operating pressure of the machine is 6 bar.
Checking the pressure
1. Check the pressure on the pressure gage (1) every day.
Important: The pressure must never deviate from the standard
value by more than 1 bar.
Setting the pressure
1. Pull the pressure controller (2) up.
2. Turn the pressure controller until the pressure gage (1) indi-
cates 6 bar.
NOTICE
Machine damage possible due to incorrect pressure.
Incorrect pressure can result in damage to the machine.
Check the pressure every day.
Have the pressure reset by qualified specialists if it deviates
from the standard value.
(1) - Pressure gage (2) - Pressure controller
①
②