Operation Manual
Settings via software (sewing automat)
Instruction manual 550-532 - 00.0 - 07/201566
7.21.3 Setting parameter U085
Parameter U085 must be set after new software has been loaded.
Prerequisite:
• Machine is in programming mode, Ready key LED is off.
1. Press and hold the Memory key for 6 s.
The key LED illuminates.
2. Use the +/- Program keys to set parameter number U085.
3. Press the Ready key.
4. Use the +/- Function keys to enter a function value of 1.
5. Press the Ready key.
6. Press the Memory key.
The key LED goes out.
7.21.4 Checking the software version
1. Press and hold the Memory key for 6 s.
The controller beeps twice, the key LED lights up.
2. Press the +/- Program keys and select parameter U097.
3. Press the Ready key.
The current software versions are displayed:
• M X.XX = Main program
• P X.XX = Control panel
• T X.XX = Servo motors
• A X.XX = Seam patterns
4. Press the +/- Function keys and check the respective
software version.
5. Press the Ready key.
6. Press the Memory key.
The key LED goes out.