Operating instructions
Table Of Contents

8. Error messages
Number Error position Description Cause Error elimination
1052 Sewing motor Overcurrent - Sewing motor cable
- Sewing motor
- Control
- Check sewing motor cable
- Check sewing motor
- Check control
1053 Sewing motor Overvoltage Mains too high
- Check mains voltage
1055 Sewing motor Overload - Sewing motor (blocked/
rough running)
- Control
- Check sewing motor
- Check control
1056 Sewing motor Excess temperature - Sewing motor
(rough running)
- Control
- Check sewing motor
- Check control
1058 Sewing motor Speed - Sewing motor
- Check sewing motor
1059 Sewing motor Standstill-
monitoring
- Sewing motor
- Reference switch
- Check sewing motor
- Check reference switch
1120 Sewing motor Initialization - Sewing motor
- Sewing motor cable
- Reference switch
- Check sewing motor
- Check sewing motor cable
- Check reference switch
1205 Sewing motor Not in UDC
(Upper Dead Center)
- Sewing motor
- Sewing motor cable
- Reference switch
- Switch machine off/on
- Check sewing motor
- Check sewing motor cable
- Check reference switch
1301 Sewing motor Referencing
timeout
- Reference switch
- Sewing motor
- Control
- Check reference switch
- Check sewing motor
- Check control
1302 Sewing motor Current feed
error
- Sewing motor
- Sewing motor cable
- Control
- Check sewing motor
- Check sewing motor cable
- Check control
1310 Sewing motor Communication-
problem
- Sewing motor
- Sewing motor cable
- Reference switch
- Check sewing motor
- Check sewing motor cable
- Check reference switch
1320 Sewing motor General sewing motor
error
- Sewing motor
- Sewing motor cable
- Reference switch
- Check sewing motor
- Check sewing motor cable
- Check reference switch
2101 Step motor
x-axis
Referencing
timeout
- Reference switch
- Step motor
- Control
- Check reference switch
- Check step motor
- Check control
2152 Step motor
x-axis
Overcurrent - Step motor
- Control
- Check step motor
- Check control
2153 Step motor
x-axis
Overvoltage - Step motor
- Control
- Check step motor
- Check control
2155 Step motor
x-axis
Overload - Step motor
- Control
- Check step motor
- Check control
2156 Step motor
x-axis
Excess temperature - Step motor
- Control
- Check step motor
- Check control
41