Operating instructions

3.4 Changing the needle
Caution: Danger of injury !
Switch off at main power switch ! Only change the needle when the
sewing automat is switched off !
Loosen screw 1.
Pull needle form the needle bar.
Insert the new needle to the stop in the bore of the needle bar.
Set the needle so that the needle scarf lies on the backward facing
side of the knife.
Tighten screw 1.
CAUTION !
If the needle thickness is changed, the distance between the hook
and the needle may need to be changed.
10
1