3.4 Changing the needle
Caution: Danger of injury !
Switch off at main power switch ! Only change the needle when the
sewing automat is switched off !
–
Loosen screw 1.
–
Pull needle form the needle bar.
–
Insert the new needle to the stop in the bore of the needle bar.
–
Set the needle so that the needle scarf lies on the backward facing
side of the knife.
–
Tighten screw 1.
CAUTION !
If the needle thickness is changed, the distance between the hook
and the needle may need to be changed.
10
1