Operating instructions
8. Oil lubrication
Caution: Danger of injury !
Oil can cause skin eruption.
Avoid protracted contact with the skin.
In the event of contact, thoroughly wash the affected area.
ATTENTION !
The handling and disposal of mineral oils is subject to legal
regulations.
Deliver used oil to an authorized collecting s tation.
Protect your environment.
Take care not to spill oil.
Fill up the oil reservoirs exclusively with lubricating oil
DA-10 or an equivalent oil with the following specification:
–
Viscosity at 40°C: 10 mm²/s
–
Ignition point: 150°C
The oil can be bought at the sales points of DÜRKOPP ADLER AG
under the following parts numbers:
250-ml-Container: 9047 000011
1-Litre-Container: 9047 000012
2-Litre-Container: 9047 000013
5-Litre-Container: 9047 000014
8.1 Filling the oil reservoir
–
Fill the oil reservoirs 1 and 2 through the hole in the inspection
glasses.
–
The oil level has to be between min. and max.
20