Operating instructions

8.2 Thread take-up spring and thread regulator
Standard:
While the thread lever is moving down from its upper dead center, the
thread take-up s pring should hold the thread tight until the needle
penetrates the fabric.
Setting of the thread controller spring:
Loosen screw 1.
Turn ring 2 for altering the tension.
Turn case 3 for altering the spring travel.
(Spring travel 2-3 mm)
Tighten screw 1 again.
Setting of the thread regulator:
Loosen screw 4.
The distance 5 (inner flanks of the thread regulator) s hould be set
to 5 mm.
Tighten screw 4.
Note:
To obtain an optimal thread take-up with thick material, the regulator
should be shifted to the rear. The optimal position can be determined
through sewing tests.
27
3
2
1
3
4
5