Operating instructions

6. Hook and needle bar
6.1 Needle position
Standard:
The needle (80 Nm) should have a distance of 1.8 mm to the front
edge of the knife.
Setting:
Loosen screw 3 through drill-hole 4 in the arm.
Shift the needle bar linkage 5 according to the instructions.
Tighten screw 3 again.
Attention
After correcting the needle position check the distance between hook
and needle (chapter 6.4) and adjust it, if required.
6.2 Reference position of the needle bar
Standard proximity sw itch :
The distance between the proximity switch 6 and the switching
edge 7 should amount 0.7 mm.
Functional check :
Select the input 17 in the Multitest-Input test. On recognition of the
switching edge the switching status must change form “-” to “+”.
21
3
3
5
4
6
7