Operation Manual

8.8.3 Machine error
Error Description Possible cause Troubleshooting
code
1051 Sewing motor time
out
- Cable to sewing motor
ref ere n ce s w it c h fa u lt y
- Sewing motor faulty
- Machinery not running
smoothly
- Check cable
Ch e ck re fe re nc e s w it c h
- Check sewing motor
- Check mechanics
1055 Sewing motor
overload
- Sewing motor blocked
/not running smoothly
- Sewing motor faulty
- Control unit faulty
- Cable for sewing motor
not plugged in or faulty
- Cable for incremental encoder
not plugged in/ faulty.
- Eliminate the blockage/ stiffness
- Check sewing motor
- Check control unit
- Connect or check sewing motor
cable
- Connect or check incremental
encoder
cable
1342
1343
Sewing motor error Internal error
- Switch machine
off and on again
- Update software
- Inform DA service
2101 X axis step motor
time out referencing
- Reference switch
cable faulty
- Reference switch faulty
- Step motor faulty
Machinery not running
smoothly
- Check cable
Ch e ck re fe re nc e s w it c h
- Check step motor
- Check mechanics
2103 Step loss test:
Step losses on
Xaxis
Stitch length in the contour in
the X direction too great
- Reduce speed
- Scale contour smaller in X
direction
- Reduce stitch length in the
contour in
the X direction
2165
2167
Step motor data
-Xaxis
Internal error
- Switch machine
off and on again
- Update software
- Inform DA service
2201 Y axis step motor
time out referencing
- Reference switch
cable faulty
- Reference switch faulty
- Step motor faulty
- Machinery not running
smoothly
- Check cable
Ch e ck re fe re nc e s w it c h
- Check step motor- Check
mechanics
2203 Step loss test:
Step losses on
Yaxis
Stitch length in the contour in
the Y direction too great
- Reduce speed
- Scale contour smaller in Y
direction
- Reduce stitch length in the
contour in
the Y direction
2265
_
2267
Step motor data
-Xaxis
Internal Error
- Switch machine
off and on again
- Update software
- Inform DA service
2911
2914
Step motor error Inter nal error
- Switch machine
off and on again
- Update software
- Inform DA service
3100 Machine control
voltage
Temporary power failure
Check mains voltage
3101 Machine power
voltage
Temporary power failure
Check mains voltage
85