Operation Manual
Input test
The input components to be tested are selected with this test
function.
CAUTION!
The input components are set carefully at the factor.
Configuring and correcting them must only be done by trained service
personnel.
–
Start the test function by pressing OK.
–
Select the required input component by pressing “?”or“?”.
The switching status of the input component is displayed.
–
To exit the test function press ESC.
The Multi-test menu appears.
Input component Function
S1 Manual switch 1, if the option is activated
S2 Manual switch 2, if the option is activated
S14 Pedal A
S15 Pedal B
S16. Pedal C
S17 Pedal D
N ref. Sewing motor reference switch
X ref . X ref ere n ce s w it c h
Y ref . Y re fe ren c e s wi t ch
The current assignment of the inputs is specified in the Fittings menu
in the “Assignment of inputs” sub menu.
Cf. also paragraph 8.7 Distributor circuit board
56
Eingang S14: -
Eingangstest