Operation Manual
Times sub menu
Waiting time between pedal position 1 (lower clamping foot) and
start of sewing (t1).
Time only relevant with rapid start using the pedal or the hand switch
(optional).
Enter: 50 ...300 ms
Default value: 150 ms
Switch on time for thread wiper magnet (t2)
This menu item is only displayed if the electrical thread wiper option is
switched on in the Fittings menu.
Enter: 30 ...100 ms
Default value: 40 ms
Time when thread wiper magnet off - clamping foot magnet on (t3)
Waiting time between the thread wiper magnets being switched off
and the clamping foot magnets being switched on.
This menu item is only displayed if the electrical thread wiper option is
switched on in the Fittings menu.
Enter: 0 ...300 ms
Default value: 50 ms
Waiting time between clamping foot magnet coming on and the
ref e re n ce r u n ( t4 ) .
Waiting time between the clamping foot magnets being switched on
and the step motors being referenced.
Enter: 0 ...300 ms
Default value: 70 ms
Time for activating energy saving mode (t5)
Waiting time between any operating component being operated
(control panel, pedal, manual switch) until energy saving mode is
activated.
Enter: 0 … 60 min 0 = energy saving mode
switched off
47
1
t1: 100
t2: 120
t3: 50
t4: 70
t5: 15