Operation Manual
8.4 Sewing pattern
There are three different sewing patter n types available for the button
sewer 531.
·
Fixed standard sewing pattern (type 1) (See section 11)
The length, width and sewing speed parameters can be changed
in sewing mode. The laser marking lights can be switched on and
off. The changes are saved.
After selecting another sewing pattern the c hanges are lost,
however.
Sewing patter n numbers 1 - 50 are available for this sewing
pattern that cannot be deleted or overwritten.
·
Programmable sewing patter n (type 2)
Fixed standard sewing patterns can be changed at programming
level (length, width, sewing speed, laser light 1 - 8) and saved
under a new program number.
Sewing patter n numbers 51 - 90 are available for this sewing
pattern that can be changed or overwritten.
·
Free seam contours (type 3)
Sewing patter n numbers 91 - 99 are available for these seam
contours. How to create free seam contours is described in
Section 8.6.5.4.
The length, width and sewing speed parameters can be changed
in sewing mode. The laser marking lights can be switched on and
off. The changes are saved.
When another sewing patter n is selected the changes are lost,
however.
·
25 sewing pattern sequence programs each with up to 20 sewing
patterns for each sewing patter n sequence program can be
created and saved.
8.5. Energy saving mode
The energy saving mode is selected after a time that can be set (1 - 60
minutes) or switched off completely (0 minutes) by using t5 in the
Machine configuration/timesmenu.
When this is selected the clamping foot is lowered to save energy and
thus reduce the amount of heat developed too.
The set time expires if no user entries are made via the control panel,
pedal or manual switch.
Before selecting the energy saving mode the message flashes twice
as an indication that the clamping foot will be lowered immediately.
Then the message stays on the screen.
Normal mode is enabled again. The clamping foot is raised and the
message deleted if the user makes an entry using the control panel,
pedal or manual switch.
The machine is now ready for operation immediately.
23
1
Energiespar-Modus