Operation Manual

Function button Function
If no input box is selected:
Switch between the rows in the menus.
The selected line is shown inversely.
If an input field is selected:
Increase or reduce the value of the relevant position by one or with
functions with several alter native options switch between the
parameters.
OK button If no input field is selected:
Select the input field.
The value can be changed with the ñ “and“ò keys.
If an input field is selected:
The set value will be applied.
If the clamping foot has been lowered by pressing OK + F:
The test sequence starts.
ESC button If the test functions have started (Multitest / 180° disc):
You go back to the selection menu.
If an input box has been selected:
An entry is cancelled.
The previous value is retained.
At t echnician, programming level
The control unit switches to sewing mode.
In sewing mode
raise clamping foot and cancel sewing procedure.
P button The control unit switches from sewing mode to programming mode.
In this mode changed stitch patter ns can be saved under a new
program number.
S button The control unit switches from sewing mode or sewing pattern
programming mode to the sequence programming mode.
In this mode new sequences can be created or existing ones modified.
F button The control unit switches from sewing mode to technician mode.
This mode can only be selected by entering a code.
In this operating mode basic machine parameters can be set and
diagnosis and setting programs can be called up.
19
1