Operating instructions

Error Description Possible causes Troubleshooting
code
2201 Step motor Y-axis
timeout referencing
· Cable to reference switch
faulty
· Reference switch faulty
. Step motor faulty
. Mechanics rough-running
· Check cable
· Check reference switch
. Check step motor
. Check mechanics
2252 Step motor Y-axis
overcurrent
· Step motor Y-axis faulty
· Control faulty
· Check step motor Y-axis
· Check control
2253 Step motor Y-axis
overcurrent
Too high mains voltage
Check mains voltage
2256 Step motor Y-axis
overheated
· Step motor Y-axis
rough running
· Step motor Y-axis faulty
· Control faulty
· Remove cause of rough running
· Check step motor Y-axis·
· Check control
2262 Step motor Y-Axis
IDMA Autoincrement
Breakdown
Switch the sewing machine off
and on again
2911
-
2914
Step motor error Internal error
· Switch machine off and on again
· Software update
· Contact the DA-Service staff
3100 Machine voltage
control
Temporary mains voltage
drop
Fuse F403 faulty
Check mains voltage
Replace fuse F403
3101 Machine power
voltage
Temporary mains voltage
drop
Fuse F402 faulty
Check mains voltage
Replace fuse F402
3102 Machine
voltage error
intermediate circuit
sewing motor
Temporary mains voltage
drop
Fuses F400/F404 faulty
(ext.)*
Check mains voltage
Replace fuses F400/F404 (ext.)
3103 Machine
intermediate circuit
step motor
Temporary mains voltage
drop
Fuse F401 faulty
Check mains voltage
Replace fuse F401
3107 Machine
temperature
· Vent holes blocked
· Ventilation grid soiled
· Check the vent holes
· Clean the ventilation grid
3215 Machine hook thread
counter zero
The counter for the hook
thread counter is zero : the
bobbin is empty
Confirm the message and replace
the bobbin.
* Those fuses could also be faulty when the control unit does not react and/or powering up does nothing!
82