Operating instructions
8.6.3 Machine errors
Error Description Possible causes Troubleshooting
code
1051 Sewing motor timeout · Cable to motor faulty
· Reference switch faulty
. Sewing motor faulty
. Mechanics rough-running
· Check cable
· Check reference switch
. Check sewing motor
. Check mechanics
1052 Sewing motor
overcurrent
· Cable to motor faulty
· Sewing motor faulty
· Control faulty
. Software not compatible to the
control unit version (A/Bxx.x)
· Check cable
· Check sewing motor
· Check control
. Check the serial number of the
DAC III control unit
1
, if necessary
load the correct software version.
1053 Sewing motor
overvoltage
- Mains voltage too high
- Check mains voltage
1055 Sewing motor
overload
· Sewing motor is blocked /
rough running
· Sewing motor faulty
· Control faulty
· Remove cause of block / rough
running
· Check sewing motor
· Check control
1056 Sewing motor
overheated
· Sewing motor rough running
· Sewing motor faulty
· Control faulty
· Remove cause of rough running
· Check sewing motor
· Check control
1058
1059
Motor speed
(inverted)
Sewing motor faulty
Check sewing motor
1062 Sewing motor IDMA
autoincrement
Breakdown
Switch machine off and on again
1302 Sewing motor power
source error
-Plug for sewing motor
not plugged in
-Plug for incremental
sensor not plugged in
- Connect the plug for the sewing
motor
- Connect the plug for the
incremental sensor
1342
-
1344
Sewing motor error Internal error
· Switch machine off and on again
· Software update
· Contact the DA-Service staff
2101 Step motor X-axis
timeout referencing
· Cable to reference switch faulty
· Reference switch faulty
. Step motor faulty
. Mechanics rough-running
· Check cable
· Check reference switch
. Check step motor
. Check mechanics
2152 Step motor X-axis
overcurrent
· Step motor X-axis faulty
· Control faulty
· Check step motor X -axis
· Check control
2153 Step motor X-axis
overcurrent
Mains voltage too high
Check mains voltage
2156 Step motor X-axis
overheated
· Step motor X-axis
rough running
· Step motor X-axis faulty
· Control faulty
· Remove cause of rough running
· Check step motor X -axis
· Check control
2162 Step motor Y-axis
IDMA autoincrement
Breakdown
Switch machine off and on again
1
Serial numbers 0302-00101 ... 0307-00643: the control unit should be used with an Axx.x-Version
Serial numbers 0307-00644 and higher: the control unit should be used with an Bxx.x-Version
1