Service manual
Appendix
Service manual 512/532 Version 00.0 - 12/2013 63
14 Appendix
14.1 Software error messages
The remedial measures are to be processed in the order specified.
Error Meaning Possible cause
Remedial measures
Process in the order specified!
E 8 Error table data Unable to read the table
data
• Save the table data again.
E 1 0 Error sewing pattern
number
The selected sewing
pattern is not saved in
ROM or is set to non-
readable. The sewing
pattern is "0"
• Press the Reset button to confirm the
sewing pattern number.
E 3 0 Error needle bar
position top
The needle bar is not at the
top position
• Check the connections.
• Turn the needle bar to the top dead center
position.
E 4 0 Error sewing field Sewing field exceeded • Press the Reset button.
• Check X/Y scaling.
E 4 2 Error scaling Sewing length is below
10 mm
• Press the Reset button.
• Check sewing pattern and X/Y scaling.
E 4 5 Error sewing pattern
data
Sewing pattern data cannot
be applied
• Press the Reset button.
• Check ROM.
E 5 0 Pause Reset button pressed while
sewing.
Sewing machine stopped.
• Press the Reset button.
• Actuate the thread trimmer.
• Restart the sewing process.
E 3 0 2 Error machine head Machine head has moved. • Fold back machine head.
E 3 0 5 Error thread trimmer
position
Thread trimmer blade not
at home position
• Set main switch to OFF.
• Check sensor.
E 3 0 6 Error thread catcher
position
Thread catcher not at home
position
• Set main switch to OFF.
• Check sensor.
E 3 3 2 Error clamp foot
position
Clamp foot not at home
position
• Set main switch to OFF.
• Check sensor.
E 5 0 1 Data read error Data not available or in the
wrong format
• Save the data to a USB stick again.
E 5 0 2 USB read error MOT file error • Save the data to a USB stick again.
E 5 0 3 SUM read error CHECKSUM data error in
MOT file
• Save the CHECKSUM file to a USB stick
again.
E 5 0 4 End block error No end block in the MOT
file
• Save the end block file to a USB stick
again.
E 5 0 5 USB read error USB stick not found • Set main switch to OFF.
• Set main switch to ON.
• Reinsert USB stick.
E 5 0 6 USB read error Unable to read U01 ~ U10. • Set main switch to OFF.
• Set main switch to ON.