Service manual
Adjusting the light barriers
Service manual 512/532 Version 00.0 - 12/2013 21
Adjusting steps
1. Loosen the screw (1).
2. Adjust the switching flag (2) accordingly.
3. Set the zero point via the control unit.
4. Tighten the screw (1).
5. Reference the machine.
4.3 Thread clamp switching flag
The thread clamp switching flag is used as reference by the control unit for
the thread clamp. The switching flag is located underneath the throat plate
to the right and is factory set.