Operating instructions

10.2 Oil lubrication
Caution Risk of Injury !
Oil can cause skin rashes.
Avoid prolonged skin contact.
If oil or grease contacts your skin, wash yourself thoroughly.
CAUTION !
The handling and disposal of mineral oils is subject to legal
constraints.
Deliver used oil to an authorized reception point.
Protect your environment.
Take care not to spill any oil.
Oil the automatic bartacker exclusively with the lubricating oil DA-10 or
equivalent oil with the following specification:
Viscosity at 40° C: 10 mm²/s
Flash point: 150° C
DA-10 can be purchased at sales branches of
DÜRKOPP ADLER AG, under the following part numbers:
250-ml container: 9047 000011
1-litre container: 9047 000012
2-litre container: 9047 000013
5-litre container: 9047 000014
Maintenance required Explanation Operational interval, hours
Lubricating the automatic
bartacker
The automatic bartacker is equipped with
central oil wick lubrication. The bearings are
supplied by the oil reservoirs 2 and 3.
- The oil level must not drop below the r ed
marking of both reservoirs.
- Fill up oil though the drill-hole 1, u p to the
red mark.
8
1
89
32
1