10. Maintenance
10.1 Cleaning and checking
Caution – Risk of Injury !
Turnthemainswitchoff.
Maintenance work of the automatic bartacker must only be
carried out when the machine is switched off.
All maintenance work must be carried out before o r at the maintenance
intervals defined in the table (refer to the “operational hours” column).
When working with materials that are thick and fibrous, shorter
maintenance intervals may be required.
A clean automatic bartacker helps to prevent malfunctions.
Maintenance required Explanation Operational interval
Maintenance w ork
Machine head
- Remove sewing dust and
residual thread (you can use
compressed air).
Important points to be cleaned:
- The area under the throat plate
- The area around the hook 1
- The bobbin enclosure
- The thread trimmer
- The area around the needle 2
8
Control box
- Clean fan grill
8