Operating instructions
8.7 Distributor PCB
The distributor PCB is located at the back of the machine below the
clamping foot magnet. All control unit inputs and outputs are
accessible from here. The rear cover must be removed in order to gain
access to the terminals.
Description of the outputs
Output number Output Assignment
Y1 (FW/FK) 24V / 4 A Thread clamp magnet / optional: Thread wiper
magnet
Y2 24V / 0.5 A -
Y3 24V / 3 A -
Y4 (FS) 24V / 4 A* Thread tension magnet
Y5 24V / 0.5 A Optional: Magnetic valve for the “separated
clamping foot 1"
Y6 24V / 0.5 A Optional: Magnetic valve for the “separated
clamping foot 2"
Y7 - Y12 24V / 0.5 A -
Y13 (FA) 24V / 3 A* Thread trimmer magnet
Y14 - Y17 24V / 0.5 A -
Y18 - Y19 24V / 6.5 A* -
Y21 - Y23 24V / 0.2A Optional: Laser marking light 1 – 3
Y24 - Y28 24V / 0.2A -
Y31(X11/ X12: FL) 60V / 8A(2A) Clamping foot magnet
*: Output is PWM-compatible
Magnets and magnetic valves are connected between +24V (X9) and
the corresponding output (X8, X10).
78