Operating instructions

Input test
With this testing function, the input element to be tested is selected.
CAUTION !
The input elements have been carefully adjusted in the factory.
Adjusting and correcting should only be carried out by trained service
staff.
Caution Risk of Injury !
Do not reach into the working area of the machine when starting and
ending the input tests.
Start the test function with the OK key.
Select the desired input element with the ñ and ò”keys.
The switching status of the input element is indicated.
Press the function key ESC” in order to leave the test function.
The Multitest menu is displayed.
Input element Function
S 1 Hand switch 1, if the option is activated
S2 Hand switch 2, if the option is activated
S14 Pedal A
S15 Pedal B
S16 Pedal C
S17 Pedal D
Ref. N Referencing switch for the sewing motor
Ref. X X-reference switch
Ref. Y Y-reference switch
Also refer to the Distributor PCB section
The current configuration of the inputs is indicated in the sub-menu
“Input configuration” in the Configuration menu.
1
53
==== Input test =====
Input S1: +