Operating instructions
Input test
With this testing function, the input element to be tested is selected.
CAUTION !
The input elements have been carefully adjusted in the factory.
Adjusting and correcting should only be carried out by trained service
staff.
Caution – Risk of Injury !
Do not reach into the working area of the machine when starting and
ending the input tests.
–
Start the test function with the “OK” key.
–
Select the desired input element with the “ñ” and “ò”keys.
The switching status of the input element is indicated.
–
Press the function key “ESC” in order to leave the test function.
The Multitest menu is displayed.
Input element Function
S 1 Hand switch 1, if the option is activated
S2 Hand switch 2, if the option is activated
S14 Pedal A
S15 Pedal B
S16 Pedal C
S17 Pedal D
Ref. N Referencing switch for the sewing motor
Ref. X X-reference switch
Ref. Y Y-reference switch
Also refer to the “Distributor PCB ” section
The current configuration of the inputs is indicated in the sub-menu
“Input configuration” in the Configuration menu.
1
53
==== Input test =====
Input S1: +