Operating instructions

PWM output test
This testing function checks the function of the magnets.
Start test function with the OK key.
Select the desired output element by pressing the ñ”or“ò”keys.
Switch the selected output element on and off by pressing the OK
key.
The present electricity, flowing through the clamping foot solenoid
will be displayed.
If the machine is equipped with a monitoring switch for the
clamping foot, the Output PWM-1 will have the value + or -,
according to the switching status of the output element.
Press the function key ESC” in order to leave the testing function.
Caution Risk of Injury !
Do not reach into the running machine during the functional test of the
output elements.
Output element Function
Y31 Clamping foot magnet
Also refer to the Distributor PCB section
52
== PWM output test ==
Output Y31: 0