Operating instructions
Output test
With this testing function, the function of the output elements is
checked.
–
Start testing function with the “OK” key.
–
Select the desired output element by pressing the “ñ”or“ò”keys.
–
Switch the selected output element on and off by pressing the “OK”
key.
–
Press the function key “ESC” in order to leave the testing function.
Caution – Risk of Injury !
Do not reach into the running machine during the function test of the
output elements.
Output-
element Function
Y1 Thread clamp/thread wiper (option)
Y2 Magnetic valve for the pneumatic sewing foot lift
Y4 Thread tension
Y13 Thread trimmer magnet
Y18 Separated clamping foot 1, if the option is activated
Y19 Separated clamping foot 2, if the option is activated
Y21 Laser marking light 1, if the option is activated
Y22 Laser marking light 2, if the option is activated
Y23 Laser marking light 3, if the option is a ctivated
Also refer to the “Distributor PCB ” section
The current configuration of the outputs is indicated in the sub-menu
“Output assignments” in the “Configuration” menu.
1
51
==== Output test ====
Output Y1: +